DESCRIPTION
BIO-FIX (LV) is formulated for
effective field application by brush, roller or plural component heated
airless sprayer. The BIO-FIX (LV) formulation is based on the unique
BIO-FIX resin system which may be applied to damp or wet surfaces. This
resin system is toughened with *KevlarTM fibres to give superior chip
resistance and is pigmented with select hard ingredients to further
enhance wear resistance.
The cured film is glossy with a slight
texture resulting from the fibre reinforcement. Related products have been
employed for underwater application and have been subjected to both
radiation and DBA testing with excellent results. The resin system used
has excellent resistance to commodities such as hydrocarbon oils and
fuels, mineral acids and alkali.
The solvent-free formulation
avoids the objectionable odour and explosion hazards of epoxy solvents.
Absence of solvents also assures compliance with all present and proposed
air pollution regulations and prevents common service problems caused by
shrinkage or water sensitivity of residual entrained solvent
residues.
*Trademark E.I. DuPont de Nemours Co.
USES
SECONDARY
CONTAINMENT Excellent chemical and impact resistant properties are
ideal for tank linings, pits, etc.
SURFACE
REINFORCEMENT KevlarTM fibre enhancement adds physical strength to
BIO-FIX (LV) excellent chemical strength.
WASTEWATER TREATMENT Reinforcing, smoothing and
protecting worn concrete damaged by exposure to chemical or municipal
waste systems.
APPEARANCE
COLOUR Black, White, Grey, other
colours available (slight yellowing)
FINISH
Gloss with slight texture
PHYSICAL PROPERTIES
VEHICLE
TYPE Epoxy/Aliphatic Polyamines
PIGMENTATION Colour/Fibrous reinforcing/Inert
extender
CLEANER M.E.K. or Lacquer thinner
MIXING RATIO 5.0/3.0 (Volume)
INDUCTION TIME Not required
POT LIFE Approx. 30 minutes/77 degrees F (25 degrees
C)
SOLIDS BY VOLUME 100%
REC. DRY THICKNESS 12 - 24 mils (.3 - .6 mm)
DRY TIME (TOUCH) Approx. 4 Hrs/77 degrees F
(25 degrees C)
DRY TIME (HARD) Approx. 15
Hrs/77 degrees F (25 degrees C)
THEO. SPREAD
RATE 100 sq. ft./gal. @ 16 mils; 200 sq.ft./gal.@ 8 mils 2.5 sq.m/l
@ .4mm; 5 sq.m.l @ .2mm
APPLICATION METHOD
Roller
SHELF LIFE 12 Months minimum VOC
Zero
SAFETY INFORMATION
LINK TO MEDICAL &
ENVIRONMENTAL PAGE
FLASH POINT Over 200 degrees F or
93 degrees C (Closed Cup)
STORAGE
CONDITIONS Normal, Freezing OK
SURFACE PREPARATION
Steel For heavy duty applications it
is always preferable to abrasive blast in order to assure maximum
performance. BIO-FIX (LV) is extremely tolerant of compromised surface
preparation where tight rust of existing coating residues must be
overcoated. The solvent-free formula of BIO-FIX (LV) allows applications
over existing coatings without softening or swelling, in fact, even
Styrofoam¨ may be successfully coated with this material. To ensure
adhesion over previously epoxy coated surface by abrasive blasting or
other means to provide an anchor profile.
New concrete surfaces
must be abrasive blasted or acid etched to remove the superficial layer of
laitence. Treat existing coatings as for steel.
Underwater
Surfaces Abrasive blast to remove marine growth and corrosion then apply
by roller within 45 minutes of surface preparation.
APPLICATION
BIO-FIX (LV) is supplied in
two gallon (7.6 litres) units. 1.33 gallons (5 litres) of epoxy base are
filled into a two gallon plastic pail and 0.67 gallons (2.5 l) of curing
agent are filled into a one gallon steel can to yield a 2/1 mixing ratio.
Stir the curing agent into the base preferably using a mechanical mixer.
Once mixing is complete, start application immediately - BIO-FIX (LV) does
not require a "sweat-in" or induction time. Potlife is about 30 minutes at
77 degrees F (25 degrees C), small amounts of epoxy solvent may be added
if the mixture begins to thicken noticeably towards the end of its working
life. Apply BIO-FIX (LV) using brush or roller. Underwater application is
best made using rollers or paint pads after surface preparation by
air/abrasive or high pressure water blasting to remove loose surface
contamination and marine biological fouling.
TEMPERATURE
Temperature
will exert a considerable influence on the rate of curing of chemically
cured coatings such as BIO-FIX (LV). In broad terms expect each 10 degrees
C, (18 degrees F), rise or fall in temperature to half or double dry times
and pot lives.
TRANSPORTATION
USDOT, IATA & IMO "Non-Regulated"
NOTES
SAFETY: This is a hazardous material if
misused. Read and understand the Material Safety Data Sheet (MSDS) before
use.
WARRANTY DISCLAIMER: The
technical data given herein has been compiled for your help and guidance
and is based upon our experience and knowledge. However, as we have no
control over the use to which this information is put, no warranty,
express or implied is intended or given. We assume no responsibility
whatsoever for coverage, performance or damages, including injuries
resulting from use of this information or of products recommended
herein.